Mindman RCA Series: Sensor(Solid-State PNP) – RPAE-3M

Mindman RCA Series: Sensor(Solid-State PNP) – RPAE-3M

$21.00

Sensor, Solid-State PNP, Wiring Method: 3-Wire, Switch Logic: Electronic Solid-State N.O. Type, Wire Length: L=3000mm

Availability: 10000 in stock

SKU: RPAE-3M Category: Tag: Brand:
SKU: RPAE-3M

Features
● Model RCA, RDA, RNA, RNAE, RPA, RPAE
● Wiring Method RCA, RDA: 2-Wire, RNA, RNAE, RPA, RPAE: 3-Wire
● Switch Logic RCA: SPST N.O. Type, RDA, RNA, RNAE, RPA, RPAE: Electronic Solid-State,N.O. Type
● Contact Type RCA: Reed, RDA: Solid-State, RNA, RNAE: Solid-State NPN, RPA, RPAE: Solid-State PNP
● Operating Voltage Range RCA: 5~240V DC/AC, RDA: 5~30V DC, RNA, RNAE, RPA, RPAE: 5~30V DC
● Max Switching Current RCA: 100mA max. RDA: 50mA max. RNA, RNAE, RPA, RPAE: 200mA max.
● Contact Capacity RCA: 10W max. RDA: 1.5W max. RNA, RNAE, RPA, RPAE: 6W max. (¡ù1)
● Current Consumption RNA, RPA: 15mA@24V DC max. RNAE, RPAE: 6mA@24V DC max.
● Internal Voltage Drop RCA: 3.5V max. RDA: 3.7V max. RNA, RPA: 1.5V max. RNAE, RPAE: 0.5V max.

Specification
ItemSpecification
ModelRCA, RDA, RNA, RNAE, RPA, RPAE
Wiring methodRCA, RDA: 2 wire, RNA, RNAE, RPA, RPAE: 3 wire
Switching logicRCA: SPST N.O., RDA, RNA, RNAE, RPA, RPAE: Solid state output, normally open
Switch typeRCA: Reed switch, RDA: Without contact, RNA, RNAE: NPN current sinking, RPA, RPAE: PNP current sourcing
Operating voltageRCA: 5~240V DC/AC, RDA: 5~30V DC, RNA, RNAE, RPA, RPAE: 5~30V DC
Switching currentRCA: 100mA max. , RDA: 50mA max. RNA, RNAE, RPA, RPAE: 200mA max.
Switching ratingRCA: 10W max. RDA: 1.5W max. RNA, RNAE, RPA, RPAE: 6W max. (※1)
Current consumptionRNA, RPA: 15mA@24V DC max. RNAE, RPAE: 6mA@24V DC max.
Voltage dropRCA: 3.5V max. RDA: 3.7V max. RNA, RPA: 1.5V max. RNAE, RPAE: 0.5V max.
Leakage currentRDA: 0.1mA max. RNA, RNAE, RPA, RPAE: 0.01mA max.
IndicatorRCA, RPA, RPAE: Green LED, RDA, RNA, PNAE: Red LED
CableRCA, RDA: φ4,2C,PVC, RNA, RNAE, RPA, RPAE: φ4,3C,PVC
Temperature range−10~+70°C (No freezing)
ShockRCA: 30G, RDA, RNA, RNAE, RPA, RPAE: 50G (※2)
Vibration9G (※3)
Enclosure classificationIEC 60529 IP67
Protection circuitRCA: 1, RDA: 3,4, RPA, RNA: 2,3,4, RNAE, RPAE: 3,4 (※4)
Weight46g (2m cable)
Remark※1. Warning: Never exceed rating (watt=voltage×amperage). Permanent damage to sensor will occur.
※2. Sin wave / X.Y.Z. 3 directions / 3 times each direction / 11ms each time.
※3. Double amplitude 1.5mm / 10Hz~55Hz~10Hz(Sweep 1min) / X.Y.Z. 3 directions / 1 hour each time.
※4. 1=None / 2=Short-circuit / 3=Power source reverse polarity / 4=Surge suppression.
Order Example
RCA Order Example
Shopping Cart
Scroll to Top